User`s manual

EDS-828 Series Featured Functions
These parameters are configured on the SNMP page. A more detailed explanation of each parameter is given
below the figure.
SNMP Read/Write Settings
SNMP Versions
Setting Description Factory Default
V1, V2c, V3, or
V1, V2c, or
V3 only
Select the SNMP protocol version used to manage the switch. V1, V2c
V1, V2c Read Community
Setting Description Factory Default
V1, V2c Read
Community
Use a community string match with a maximum of 30
characters for authentication. This means that the SNMP agent
accesses all objects with read-only permissions using the
community string public.
public
V1, V2c Write/Read Community
Setting Description Factory Default
V1, V2c Read/Write
Community
Uses a community string match with a maximum of 30
characters for authentication. This means that SNMP servers
access all objects with read/write permissions using the
community string private.
private
For SNMP V3, there are two levels of privilege for different accounts to access the EDS-828. Admin privilege
allows access, and authorization to read and write the MIB file. User privilege only allows reading the MIB file,