User`s manual
EDS-600 Series User’s Manual Featured Functions
3-36
Explanation of “Current Status” Items
Now Active
Shows which communication protocol is in use: Turbo Ring, Turbo Ring V2, Turbo Chain,
RSTP, or none.
Ring 1/2—Status
Shows Healthy if the ring is operating normally, and shows Break if the ring’s backup link is
active.
Ring 1/2—Master/Slave
Indicates whether or not this EDS is the Master of the Turbo Ring. (This field appears only when
selected to operate in Turbo Ring or Turbo Ring V2 mode.)
NOTE
The user does not need to set the master to use Turbo Ring. If no master is set, the Turbo Ring
protocol will assign master status to one of the EDS units in the ring. The master is only used to
determine which segment serves as the backup path.
Ring 1/2—1st Ring Port Status
Ring 1/2—2nd Ring Port Status
The “Ports Status” indicators show Forwarding for normal transmission, Blocking if this port is
connected to a backup path and the path is blocked, and Link down if there is no connection.
Coupling—Mode
Indicates either None, Dual Homing, or Ring Coupling.
Coupling—Coupling Port status
Indicates either Primary, or Backup.
Explanation of “Settings” Items
Redundancy Protocol
Setting Description Factory Default
Turbo Ring
Select this item to change to the
Turbo Ring configuration page.
Turbo Ring V2
Select this item to change to the
Turbo Ring V2 configuration page.
Turbo Chain
Select this item to change to the
Turbo Chain configuration page
RSTP (IEEE
802.1W/1D)
Select this item to change to the
RSTP configuration page.
None Ring redundancy is not active
None