The user does not need to configure any of the switches as the master to use Turbo Ring or Turbo
Ring V2. If none of the switches in the ring is configured as the master, then the protocol will
automatically assign master status to one of the switches. In fact, the master is only used to
identify which segment in the redundant ring acts as the backup path. In the following subsections,
we explain how the redundant path is selected for rings configured for Turbo Ring, and Turbo
Ring V2.
Determining the Redundant Path of a “Turbo Ring” Ring
In this case, the redundant segment (i.e., the segment that will be blocked during normal operation)
is determined by the number of EDS units that make up the ring, and where the ring master is
located.
When the number of EDS units in the Turbo Ring is even.
Master
If there are 2N EDS units (an even number) in
the “Turbo Ring” ring, then the backup segment
is one of the two segments connected to the
(N+1)st EDS (i.e., the EDS unit directly opposite
the master).