User`s manual

EDS-600 Series User’s Manual Featured Functions
3-9
NOTE
The EDS-600 does not have a real time clock. The user must update the Current Time and
Current Date to set the initial time for the EDS-600 after each reboot, especially when the
network does not have an Internet connection for an NTP server or there is no NTP server on the
LAN.
Current Time
Setting Description Factory Default
User adjustable time. The time parameter allows configuration of the
local time in local 24-hour format.
None (hh:mm:ss)
Current Date
Setting Description Factory Default
User adjustable date. The date parameter allows configuration of the
local date in yyyy/mm/dd format.
None
(yyyy/mm/dd)
Daylight Saving Time
Daylight saving time (also know as DST or summer time) involves advancing clocks (usually 1
hour) during the summer time to provide an extra hour of daylight in the afternoon.
Start Date
Setting Description Factory Default
User adjustable
date.
The Start Date parameter allows users to enter the
date that daylight saving time begins.
None
End Date
Setting Description Factory Default
User adjustable
date.
The End Date parameter allows users to enter the
date that daylight saving time ends.
None
Offset
Setting Description Factory Default
User adjustable
hour.
The offset parameter indicates how many hours
forward the clock should be advanced.
None
System Up Time
Indicates the EDS-600’s up time from the last cold start. The unit is seconds.
Time Zone
Setting Description Factory Default
User selectable time zone
The time zone setting allows conversion from
GMT (Greenwich Mean Time) to local time.
GMT
(Greenwich
Mean Time)