User`s manual
EDS-600 Series User’s Manual Modbus/TCP Map
B-11
0x3602 1 word TR2 Ring 1 1st Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 1 Not Enable
0x3603 1 word TR2 Ring 1 2nd Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 1 Not Enable
0x3680 1 word TR2 Ring 2 status
0x0000:Healthy
0x0001:Break
0xFFFF:Turbo Ring V2 Ring 2 Not Enable
0x3681 1 word TR2 Ring 2 Master/Slave
0x0000:Slave
0x0001:Master
0xFFFF:Turbo Ring V2 Ring 2 Not Enable
0x3682 1 word TR2 Ring 2 1st Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 2 Not Enable
0x3683 1 word TR2 Ring 2 2nd Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 2 Not Enable
0x3700 1 word Turbo Chain Switch Role Mode
0x0000:Head Switch
0x0001:Member Switch
0x0002:Tail Switch
0xFFFF:Turbo Chain Not Enable
0x3701 1 word Turbo Chain 1st Port Status
0x0000:Link Down
0x0001:Blocking
0x0002:Blocked
0x0003:Forwarding
0xFFFF:Turbo Chain Not Enable