User`s manual
EDS-516A Series User’s Manual Featured Functions
3-26
Coupling—Mode
Indicates either None, Dual Homing, or Ring Coupling.
Coupling—Coupling Port status
Indicates either Primary, or Backup.
Explanation of “Settings” Items
Redundancy Protocol
Setting Description Factory Default
Turbo Ring
Select this item to change to the
Turbo Ring configuration page.
Turbo Ring V2
Select this item to change to the
Turbo Ring V2 configuration page.
RSTP (IEEE
802.1W/1D)
Select this item to change to the
RSTP configuration page.
RSTP (IEEE 802.1W/1D)
(No ports are enabled.)
Enable Ring 1
Setting Description Factory Default
Enabled Enable the Ring 1 settings
Disabled Disable the Ring 1 settings
Not checked
Enable Ring 2*
Setting Description Factory Default
Enabled Enable the Ring 2 settings
Disabled Disable the Ring 2 settings
Not checked
*You should enable both Ring 1 and Ring 2 when using the Dual-Ring architecture.
Set as Master
Setting Description Factory Default
Enabled Select this EDS-516A as Master
Disabled
Do not select this EDS-516A as
Master
Not checked
Redundant Ports
Setting Description Factory Default
1st Port
Select any port of the EDS-516A to
be one of the redundant ports.
Ring 1: port 15
Ring 2: port 13
2nd Port
Select any port of the EDS-516A to
be one of the redundant ports.
Ring 1: port 16
Ring 2: port 14
Enable Ring Coupling
Setting Description Factory Default
Enable Select this EDS-516A as Coupler
Disable
Do not select this EDS-516A as
Coupler
Not checked