Installation guide

- 15 -
Power
Input Voltage 12/24/48 VDC (9.6 to 60 VDC),
18 to 30VAC (47 to 63 Hz)
Input Current @ 24VDC 0.1 A (EDS-205A)
0.11 A (EDS-205A-M/S)
0.13 A (EDS-208A)
0.17 A (EDS-208A-M/S)
0.22 A (EDS-208A-MM/SS)
Connection Removable 4-contact terminal block
Overload Current
Protection
1.1 A
Reverse Polarity Protection Present
Physical Characteristics
Housing IP30 protection, metal case
Dimensions EDS-208A Series: 50 x 115 x 70 mm
EDS-205A: 30 x 115 x 70 mm
Weight EDS-208A Series: 275 g
EDS-205A: 175 g
Installation DIN-Rail Mounting, Wall Mounting
(with optional kit)
Environmental Limits
Operating Temperature -10 to 60°C (14 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Regulatory Approvals
Safety UL508 (pending)
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C, and
D; ATEX Class I, Zone 2, Ex nC nL IIC T4
(Pending)
EMI FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
WARRANTY
5 years