3-66
CPU Utilization
Setting Description Factory Default
Read-only
The CPU usage volume in the past 5 seconds, 30 seconds, and
5 minutes
Past 5 secs
Free Memory
Setting Description Factory Default
Read-only The immediately free memory of the switch None
Power Consumption
Setting Description Factory Default
Read-only The immediately system power consumption information. The
measurement tolerance is 7% (Unit: watts.)
None
Statistics
Access the Monitor by selecting Monitoring from the left selection bar. Monitor by System allows the user to
view a graph that shows the combined data transmission activity of all of the Moxa switch’s 18 ports. Click one
of the four options—Total Packets, TX Packets, RX Packets, or Error Packets—to view transmission
activity of specific types of packets. Recall that TX Packets are packets sent out from the Moxa switch, RX
Packets are packets received from connected devices, and Error Packets are packets that did not pass TCP/IP’s
error checking algorithm. The Total Packets option displays a graph that combines TX, RX, and TX Error, RX
Error Packets activity. The graph displays data transmission activity by showing Packets/s (i.e., packets per
second, or pps) versus sec. (seconds). In fact, three curves are displayed on the same graph: Uni-cast
packets (in red color), Multi-cast packets (in green color), and Broad-cast packets (in blue color). The graph
is updated every few seconds, allowing the user to analyze data transmission activity in real-time.