User`s manual
Moxa E Series Managed Ethernet Switch Featured Functions
3-15
There are four response actions available on the EDS E series when events are triggered.
Action Description
Trap The EDS E series will send notification to the trap server when event is triggered
E-Mail The EDS E series will send notification to the email server defined in the Email Setting
Syslog The EDS E series will record a syslog to syslog server defined in Syslog Server Setting
Relay The EDS E series support digital inputs to integrate sensors. When event is triggered, the
device will automate alarms by relay output
Severity
Severity Description
Emergency
System is unusable
Alert Action must be taken immediately
Critical Critical conditions
Error Error conditions
Warning Warning conditions
Notice Normal but significant condition
Information Informational messages
Debug Debug-level messages
NOTE
The Traffic
-Overload, Traffic-Threshold (%), and Traffic-Duration (sec.) Port
Event items are related. If you
Enable the Traffic
-Overload event, then be sure to enter a nonzero Traffic-
Threshold percentage, as well as a
Traffic
-Duration between 1 and 300 seconds.
Email Settings
Mail Server IP/Name
Setting Description Factory Default
IP address
The IP Address of your email server.
None
User Name
Setting Description Factory Default
Max. 45 of charters Your email account. None
Password Setting
Setting Description Factory Default
Password The email account password. None
Email Address
Setting Description Factory Default
Max. of 30 characters You can set up to 4 email addresses to receive alarm emails
from the Moxa switch.
None