User`s manual

Moxa E Series Managed Ethernet Switch Featured Functions
3-14
There are four response actions available on the EDS E series when events are triggered.
Action Description
Trap The EDS E series will send notification to the trap server when event is triggered
E-Mail The EDS E series will send notification to the email server defined in the Email Setting
Syslog The EDS E series will record a syslog to syslog server defined in Syslog Server Setting
Relay The EDS E series support digital inputs to integrate sensors. When event is triggered, the
device will automate alarms by relay output
Severity
Severity Description
Emergency
System is unusable
Alert Action must be taken immediately
Critical Critical conditions
Error Error conditions
Warning Warning conditions
Notice Normal but significant condition
Information Informational messages
Debug Debug-level messages
Port Event Settings
Port Events are related to the activity of a specific port.
Port Events Warning e-mail is sent when…
Link-ON The port is connected to another device.
Link-OFF The port is disconnected (e.g., the cable is pulled out, or the opposing
device shuts down).
Traffic-Overload The port’s traffic surpasses the Traffic-Threshold for that port (provided
this item is Enabled).
Traffic-Threshold (%) Enter a nonzero number if the port’s Traffic-Overload item is Enabled.
Traffic-Duration (sec.) A Traffic-Overload warning is sent every Traffic-Duration seconds if the
average Traffic-Threshold is surpassed during that time period.