System Event Settings
System Events are related to the overall function of the switch. Each event can be activated independently with
different warning approaches. Administrator also can decide the severity of each system event.
System Events Description
Cold Start Power is cut off and then reconnected.
Warm Start Moxa switch is rebooted, such as when network parameters are changed
(IP address, subnet mask, etc.).
Configuration Change Any configuration item has been changed.
Power Transition (OnOff)
Moxa switch is powered down.
Power Transition (OffOn)
Moxa switch is powered up.
Authentication Fail An incorrect password was entered.
Password Change User change account password
TACACS Authentication Fail An incorrect authentication details were entered
RADIUS Authentication Fail An incorrect authentication details were entered
RSTP Topology Changed If any Rapid Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree)
RSTP Root Changed If RSTP root has changed
Topology Changed If the Master of the Turbo Ring has changed or the backup path is activated
If the Turbo Ring path is disconnected
If the MSTP topology has changed
DI1 (OnOff)
Digital Input 1 is triggered by on to off transition
DI1 (OffOn)
Digital Input 1 is triggered by off to on transition
ABC-02 Status Detects if ABC-02-USB-T is connected or disconnected to switch
When ABC-02-USB-T automatically import/export/backup configuration
Master Changed Master of the Turbo Ring has changed
Coupling Changed Backup path is activated
Turbo Ring Break Turbo Ring path is disconnected
Web log in Any account log in to the web-based configuration console
Rate Limit On/Off When the port disabled due to the ingress throughput exceed the setting
rate limit.
Port Looping Port looping event is triggered
LLDP Table Change Nearly connected devices are changed and shown in the LLDP table