User`s manual
Moxa E Series Managed Ethernet Switch Featured Functions
3-10
Clock Mode (sets the switch’s clock mode)
Setting Description Factory Default
v1 BC Operates as an IEEE 1588 v1 boundary clock. v1 BC
v2 E2E 2-step TC Operates as an edge-to-edge IEEE 1588 v2 transparent clock
with 2-step method.
v2 E2E 1-step TC Operates as an edge-to-edge IEEE 1588 v2 transparent clock
with 1-step method.
v2 P2P 2-step TC Operates as a peer-to-peer IEEE 1588 v2 transparent clock
with 1-step method.
v2 E2E BC Operates as an edge-to-edge IEEE 1588 v2 boundary clock
v2 P2P BC Operates as a peer-to-peer IEEE 1588 v2 boundary clock
SyncInterval (sets the synchronization message time interval)
Setting Description Factory Default
0, 1, 2, 3, or 4
0 (1 s), 1 (2 s), 2 (4 s), 3 (8 s), or 4 (16 s). Supported in IEEE
1588 V1.
0
-3, -2, -1, 0, or 1 -3 (128 ms), -2 (256 ms), -1 (512 ms), 0 (1 s), or 1 (2 s).
Supported in IEEE 1588 V2.
Delay-request Minimum Interval
Setting Description Factory Default
0, 1, 2, 3, 4, or 5 Minimum delay request message interval 0 (1 sec.)
Domain
Setting Description Factory Default
_DFLT (0), _ALT(1),
_ALT(2), or _ALT(3)
Subdomain name (IEEE 1588-2002) or the domain Number
(IEEE 1588-2008) fields in PTP messages
0(default domain)
Transport mode
Setting Description Factory Default
IPv4 or 802.3/Ethernet
IEEE 1588 PTP V1 supports IPv4 only
IEEE 1588 PTP V2 supports both IPv4 and IPv6.
IPv4
Role
Setting Description Factory Default
Member or Master Set this switch to be the Member or Grand Master Member
Announce Interval (sets the announce message interval)
Setting Description Factory Default
0, 1, 2, 3, or 4 0 (1 s), 1 (2 s), 2 (4 s), 3 (8 s), or 4 (16 s) 1 (2 s)
Announce Timeout
Setting Description Factory Default
2, 3, 4, 5, 6, 7, 8, 9, or
10
The multiple of announce message receipt timeout by the
announce message interval.
3
PDelay-request Minimum Interval
Setting Description Factory Default
-1, 0, 1, 2, 3, 4, or 5 Minimal delay request message interval:
-1 (512 ms), 0 (1 s), 1 (2 s), 2 (4 s), 3 (8 s), 4 (16 s), 5(32s)
(Available in Clock Mode: v2 P2P 2-step TC, and v2 P2P BC)
0 (1 sec)
priority1
Setting Description Factory Default
0 to 255 Set first priority value; 0 = highest priority, 255 = lowest
priority.
128