Operating instructions

BAL SX302 ETH EN 3.1 13
Chapter 4 Parameterization
Menu The parameterization of the devices is carried out in a menu of the menu display.
During normal operation OnnE appears in the menu display as soon as data
arrive at the Ethernet interface.
Menu operation To reach the menu, press both menu buttons simultaneously (approx. 1 sec.) until
an audible signal is heard and menu item 01 appears in the menu display. Now,
you can navigate in the menu as follows:
Next menu item: Shortly press key [R]
Page menu items forward: Press key [R] long
Previous menu item: Double click on key [R]
Page menu items backward: Double click on [R] and keep it pressed
Next setting Shortly press key [Q]
Page settings forward: Press key [Q] long
Previous setting Double click on key [Q]
Page setting backward: Double click on [Q] and keep it pressed
The menu ends in menu item Uwith the button [R]. The settings made are either
saved (set), not saved (escape) or the factory settings are reset, depending on the
setting selected in menu item U.
Canceling the menu without saving the settings made is possible by pressing both
menu buttons longer (approx. 1 sec.) or will occur automatically if 60 seconds pass
without a menu button being pressed.
Once the menu is closed, the unit behaves in the same manner as when the
operating voltage was applied.
In the menu mode the character appears in the main display. Control of the
display is not possible in menu mode.
Menu item P In menu item P, the decimal points of the port number flash one after the other.
The digit with the decimal point flashing can be set to the value requested by
means of the menu key [Q].
Menu table The menu items are displayed in the following menu table. The factory settings are
marked with an *. Individual menu items or settings can be suppressed in another
menu item, depending on the unit version or setting.