Operating instructions
12 BAL SX302 ETH EN 3.1
Brightness The brightness of the display can be reduced with the following command:
Normal brightness: $L0
Reduced brightness: $L1
The brightness of the display can also be reduced with an H signal applied to
functional input F2 (priority compared to the commands).
For units provided with an LRD® display brightness reduction is not possible.
Blanking The display can be blanked with the following command (priority compared
to flashing):
Blanking on: $B1
Blanking off: $B0
ESC sequences The character <ESC> (1B
h
) can be used in the command instead of the §
character, e.g. <ESC>L1 instead $L1.
Power-on reset After power-on, minus signs are displayed to signalize that the unit is ready for
operation. If a display test has been preselected in menu item F, it will run
beforehand.
Charater set
0 1 2 3 4 5 6 7 8 9 A B C D E F
2
3
4
5
6
7
8
9
A
B
C
D
E
F