User`s manual
DA-710 Series Hardware Manual Hardware Installation
2-5
Connecting the Power
To power on the DA-710 embedded computer, connect the power line to the DA-710’s AC power connector
(located on the right side of the rear panel) using the power cord and then press the power button. The DA-710
offers dual power inputs for redundancy. See the following figure for detailed power cable wiring.
If the power is being properly supplied, the Power LED will light up first, and then the Storage LED will start
blinking when the Flash Disk Module is accessed during boot up. It takes about 30 to 60 seconds for the
operating system to boot up. If Power 1 or Power 2 is not functioning, the Power 1/2 Fail LED will light up. If this
happens, check the power inputs.