Specifications
Serial Media Converters >
Device Connectivity
13-3
info@moxa.com
www.moxa.com
Product Selection Guide
Device Connectivity
13
Serial-to-Fiber Media Converters
ICF-1150-M-SC/ST
ICF-1150-M-SC/ST-T
ICF-1150I-M-SC/ST
ICF-1150I-M-SC/ST-T
ICF-1150-S-SC/ST
ICF-1150-S-SC/ST-T
ICF-1150I-S-SC/ST
ICF-1150I-S-SC/ST-T
TCF-142-M-SC/ST
TCF-142-M-SC/ST-T
TCF-142-S-SC/ST
TCF-142-S-SC/ST-T
TCF-90-M/S
Optical Fiber Side
Fiber Connector
SC or ST ST
Cables Requirements
Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 μm
Multi-mode: 50/125, 62.5/125, or 100/140 μm
Transmission Distance
Single-mode: 40 km
Multi-mode: 5 km
Wavelength
Single-mode: 1310 nm
Multi-mode: 850 nm
Tx Output
Single-mode: > -5 dBm
Multi-mode: > -5 dBm
Rx Sensitivity
Single-mode: -25 dBm
Multi-mode: -20 dBm
Point-to-Point
Transmission
Half-duplex or full-duplex –
Multi-drop
Transmission
Half-duplex, fiber ring –
RS-232 Side
Connector
DB9 female Terminal block DB9 female
Signals
Tx, Rx, GND
TxD, RxD, GND
(Loop-back wiring: RTS
to CTS, DTR to DSR
and DCD)
Baudrate
50 bps to 921.6 Kbps 300 bps to 115.2 Kbps
RS-232/422/485 Side
Connector
Terminal Block –
RS-232 Signals
TxD, RxD, GND
RS-422 Signals
TxD+, TxD-, RxD+, RxD-, GND –
RS-485-4w Signals
TxD+, TxD-, RxD+, RxD-, GND –
RS-485-2w Signals
Data+, Data-, GND –
Baudrate
50 bps to 921.6 Kbps –
ESD Protection
15 KV for all signals –
Isolation
– 2 KV – 2 KV – – –
Physical Characteristics
Housing
Metal ABS + PC
Dimensions (mm)
30.3 x 70 x 115 mm 67 x 100 x 22 mm 42 x 80 x 22 mm
Environmental Limits
Operating Temperature
0 to 60°C or -40 to 85°C (for T models) 0 to 60°C
Operating Humidity
5 to 95% RH 5 to 95% RH
Storage Temperature
-40 to 85°C -20 to 75°C
Power Requirements
Source of Input Power
– – – – – –
RS-232 port (TxD, RTS,
DTR) or power input
jack
Input Voltage
12 to 48 VDC
Power Consumption
127 mA @ 12 V 163 mA @ 12 V 127 mA @ 12 V 163 mA @ 12 V 140 mA @ 12 V 20 mA @ 5 V
Voltage Reversal
Protection
Protects against V+/V- reversal –
Over Current Protection
1.1 A 1.1 A –
Standards and Certifications
Safety
UL 508 UL 60950-1 UL 60950-1
Hazardous Location
Hazardous Location: UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC – – –
EMC
CE, FCC
EMI
EN 55022 Class B, FCC Part 15 Subpart B Class B
FCC Part 15 Subpart B
Class B
EMS
EN 61000-4-2 (ESD) Level 4,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 4,
EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (PFMF) Level 3
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
IEC 61000-4-2 (ESD)
Level 2,
IEC 61000-4-3 (RS)
Level 2,
IEC 61000-4-4 (EFT)
Level 2,
IEC 61000-4-5 (Surge)
Level 3,
IEC 61000-4-6 (CS)
Level 2,
IEC 61000-4-8 (SFMF)
Level 1
Freefall
IEC 60068-2-32 – – –
Green Product
RoHS, CRoHS, WEEE RoHS, CRoHS, WEEE RoHS, CRoHS, WEEE
Reliability
Warranty
5 years (see www.moxa.com/warranty)