Specifications

TCC-80/80I Series
Serial Media Converters >
Serial Media Converters
13-20
www.moxa.com
info@moxa.com
13
Specifications
LED Port Power Indicator
Port Power Dissipation
Port Power and Optical Isolation
When installing a TCC-80 or TCC-80I converter, it is important to
pay attention to power consumption, RS-232 cable length, and RS-
422/485 transmission distance. In general, the TCC-80 and TCC-80I
obtain 50 mW of power from the power source. Standard PC COM
ports can provide 70 to 90 mW of power if the TxD, RTS, and DTR
lines are connected. Moreover, the RS-232 cable should be shorter
than 15 m (@ 9600 bps) to ensure that less power is lost from the
host/device to the TCC-80. The remainder of the supplied power is
used for transmitting the RS-422/485 signal.
The RS-232 port of the TCC-80/80I is a DB9 female socket that can
connect directly to the host PC, with power drawn from the TxD line.
Electrical 2.5 KV isolation for the TCC-80I is achieved with a photo
coupler that transforms the electrical signal into light, and then re-
transforms the light back into an electrical signal on the other side.
In this way, the two electrical circuits are completely isolated from
each other. This also protects the devices from ground loop currents,
reduces damage caused by data loss, and prevents damage to the
communication interfaces.
It’s easy enough to test the serial device with a multimeter to
determine that the serial device will provide enough power to the
media converter. However, it’s even easier to let the TCC-80I test the
device for you. Simply connect the TCC-80I to the device’s RS-232
port and set the SW4 switch to Test mode. If the patented port power
LED indicator lights up, the TCC-80I is receiving enough power. If the
LED does not light up, you will need to attach an external power source
to the TCC-80I.
RS-232 Side
Connector: DB9 female
Signals:
RS-232: TxD, RxD, GND
(Loop-back wiring: RTS to CTS, DTR to DSR and DCD)
RS-422/485 Side
Connector: Terminal Block or DB9 male
Signals:
(interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w: Data+, Data-, GND
RS-485 Data Direction Control: ADDC® (automatic data direction
control)
Serial Communication
Baudrate: 50 bps to 115.2 Kbps
ESD Protection: 15 KV
Optical Isolation: 2.5 KV rms for 1 minute (TCC-80I only)
Physical Characteristics
Housing: ABS + PC
Dimensions:
TCC-80/80I: 42 x 80 x 22 mm (1.65 x 3.15 x 0.87 in)
TCC-80-DB9/80I-DB9: 42 x 91 x 23.6 mm (1.65 x 3.58 x 0.93 in)
Weight: 50 ± 5 g
Environmental Limits
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -20 to 75°C (-4 to 167°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Power Requirements
Source of Input Power: RS-232 port (TxD, RTS, DTR) or power input
jack
Input Voltage: 5 to 12 VDC
Power Consumption:
TCC-80: 10 mA @ 5 V (with termination disabled)
TCC-80I: 20 mA @ 5 V (with termination disabled)
Standards and Certifications
Safety: UL 60950-1
EMC: CE, FCC
EMI: FCC Part 15 Subpart B Class B
EMS:
EN 61000-4-2 (ESD) Level 2,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
Green Product: RoHS, CRoHS, WEEE
MTBF (mean time between failures)
Time: 2,781,161 hrs
Database: Telcordia (Bellcore), GB
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
RS-422
SGND
232TX
232DTR
232RTS
DC 5~12V IN
232TX
232RX
TX
TX
Control
RX
TX-I
Control-I
RX-I
2.5 KV Isolation
Test
Standard
RX
+
-
+
-
+
-
Power
Indicator
DC-DC
Transceiver
Power
ADDC
232-TTL
Transceiver
RS-485-2W RS-485-4W
TxD+
TxD-
RxD+
RxD-
Data+
Data-
TxD+
TxD-
RxD+
RxD-
SGND SGND
SW4