User`s manual

CA Series User’s Manual Software Installation
3-13
2. Under Port Number, select a COM number to assign to the serial port.
Select Auto Enumerating COM Number to map subsequent ports in numerical order. For
example, if COM 3 is assigned to Port 1, then COM 4 will be automatically assigned to Port 2.
3. Select an Rx FIFO Trigger. The default value is 56 bytes (high level). Select Set the change
to all ports to use this setting for all serial ports on the module.
4. Select a Tx FIFO Size. The default value is 64 bytes (high level). Select Set the change to all
ports to use this setting for all serial ports on the module.
5. Click OK to approve the port settings. Click OK again to close the CA Series Properties
window and apply the new port settings.
Windows XP, 2003 (32-bit)
The Windows XP and 2003 (32-bit) drivers conform to the Win32 COMM API standard and
support all models in the CA Series. In the following instructions, the CA-114 is used as an
example.
Installing the Driver
1. Select Add Hardware Wizard from the Control Panel. When the wizard opens, click Next to
continue.