User`s manual
CP-132 Series Software Installation
3-12
Configuring Board and Port
If desire to re-configure the COM number for the ports of installed boards and drivers under Windows 95/98,
please follow procedures listed below.
For this is a PCI board, once the board is added or unplugged, the configuration will be automatically added or
removed by the system. Thus, it saves your effort to do add or remove action.
1. Open [Control Panel], click [System] icon, select [Device Manager] tab, and then select Moxa
Smartio/Industio multiport board.
2. Click on desired CP-132 Series board entry, and click [Properties] button.
3. Select [Ports Configuration] tab.
4. Click on the specific port and click [Port Setting] button to re-assign the desired COM number for the
Industio CP-132 Series port mapping.
NOTE
Step 5 is optional, if you want to assign COM number
s to Port manually.
5. Check Auto Enumerating COM Name check-box to assign continuous COM numbers for subsequent ports.
For example, if COM 3 is assigned to Port 1, then COM 4 will be automatically assigned to Port 2.
NOTE
Step 6 and 7 are optional, if
the system doesn’t require a special performance tuning.