NPort 6000 Series User’s Manual System Management Settings
9-11
ATTENTION
Consult your Network Administrator or ISP for the proper mail server settings. The Auto warning
function may not work properly if it is not configured correctly. The NPort 6000’s SMTP AUTH
supports LOGIN, PLAIN, and CRAM-MD5 (RFC 2554).
Mail server: This field is for your mail servers domain name or IP address.
User name: This field is for your mail server’s user name, if required.
Password: This field is for your mail servers password, if required.
From e-mail address: This is the e-mail address from which automatic e-mail warnings will be
sent.
To e-mail address 1 to 4: This is the e-mail address or addresses to which the automatic e-mail
warnings will be sent.
SNMP Trap
SNMP trap server IP: Use this field to indicate the IP address to use for receiving SNMP traps.
Trap version (default=v2): Use this field to select the SNMP trap version.
Trap community (default=public):Use this field to designate the SNMP trap community.