Installation guide
— 4 — — 5 — — 6 —
5. Software Installation Information
To install NPort Administration Suite, insert the NPort Document &
Software CD into your computer’s CD-ROM drive. Once the NPort
Installation CD window opens, click the INSTALL UTILITY button,
and then follow the instructions on the screen.
To view detailed information about NPort Administration Suite, click
the DOCUMENTS button, and then select “NPort 5600 Series User’s
Manual” to open the pdf version of this user’s guide.
6. Pin Assignments and Cable Wiring
Serial Port Pinouts
for NPort 5610
Serial Port Pinouts for NPort 5630
18
18
Pin RS-232
1 DSR (in)
2 RTS (out)
3 GND
4 TxD (out)
5 RxD (in)
6 DCD (in)
7 CTS (in)
8 DTR (out)
Pin
RS-422
4-wire RS-485
2-wire RS-485
1 --- ---
2 --- ---
3 TxD+ ---
4 TxD- ---
5 RxD- Data-
6 RxD+ Data+
7 GND GND
8 --- ---
Serial Port Pinouts for NPort 5650
Pin RS-232
RS-422
4-wire RS-485
2-wire
RS-485
1 DSR --- ---
2 RTS TxD+ ---
3 GND GND GND
4 TxD TxD- ---
5 RxD RxD+ Data+
6 DCD RxD- Data-
7 CTS --- ---
8 DTR --- ---
18
Serial Cables for NPort 5630 (2-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5630
Serial
Device
Data- 5
2 3 3 2 Data-
Data+ 6
1 1 8 8 Data+
GND 7
8 7 5 4 GND
Serial Cables for NPort 5630 (RS-422/4-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5630
Serial
Device
TxD+ 3
5 5 7 7 RxD+
TxD- 4
3 2 2 3 RxD-
RxD- 5
2 3 3 2 TxD-
RxD+ 6
1 1 8 8 TxD+
GND 7
8 7 5 4 GND
Serial Cables for NPort 5610/5650 (RS-232)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5610
NPort 5650
Serial
Device
DSR 1
6 4 6 20 DTR
RTS 2
7 8 4 5 CTS
GND 3
5 5 7 7 GND
TxD 4
3 2 2 3 RxD
RxD 5
2 3 3 2 TxD
DCD 6
1 1 8 8 DCD
CTS 7
8 7 5 4 RTS
DTR 8
4 6 20 6 DSR
Serial Cables for NPort 5650 (RS-422/4-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5650
Serial
Device
TxD+ 2
7 8 4 5 RxD+
GND 3
5 5 7 7 GND
TxD- 4
3 2 2 3 RxD-
RxD+ 5
2 3 3 2 TxD+
RxD- 6
1 1 8 8 TxD-
Serial Cables for NPort 5650 (2-wire RS-485)
RJ45 Port DB9-M DB9-F DB25-M DB25-F Serial Port
NPort 5650
Serial
Device
GND 3
5 5 7 7 GND
Data+ 5
2 3 3 2 Data+
Data- 6
1 1 8 8 Data-
7. Environmental Specifications
LAN
Ethernet
Protection
10/100 Mbps, RJ45
Built-in 1.5 KV magnetic isolation
Optical Fiber
Multi mode Single mode
Distance 0 to 2 km, 1310 nm
(62.5/125 μm, 500
MHz*km)
0 to 40 km, 1310 nm
(9/125 μm, 3.5 PS/
(nm*km))
Min. TX Output -20 dBm 0 to 40 km, -5 dBm
Max. TX Output -14 dBm 0 to 40 km, 0 dBm
Sensitivity -34 to -30 dBm -36 to -32 dBm
Serial Interface
Interface
No. of Ports
Port Type
Signals (RS-232)
Signals (RS-422)
Signals (2-wire RS-485)
Signals (4-wire RS-485)
Serial Line Protection
RS-485 Data Direction
RS-232/422/485
16/8
8-pin RJ45
TxD, RxD, RTS, CTS, DTR, DSR, DCD,
GND
Tx+, Tx-, Rx+, Rx-
Data+, Data-, GND
Tx+, Tx-, Rx+, Rx-
15 KV ESD for all signals
ADDC™ (Automatic Data Direction Control)
Power requirements
Power Input
Power Consumption
NPort 5610-8/16
NPort 5610-8/16-48V
NPort 5630-8/16
NPort 5650-8/16
NPort 5650-S-SC-8/16
NPort 5650-M-SC-8/16
100 to 240 VAC, 47 to 63 Hz,
±48 VDC (38 to 72 VDC, -38 to -72 VDC)
141 mA @ 100 VAC, 93 mA @ 240 VAC
135 mA @ 48 VDC
152 mA @ 100 VAC, 98 mA @ 240 VAC
158 mA @ 100 VAC, 102 mA @ 240 VAC
164 mA @ 100 VAC, 110 mA @ 240 VAC
174 mA @ 100 VAC, 113 mA @ 240 VAC
Operating temp. 0 to 55°C (32 to 131°F)
Operating humidity 5 to 95% RH
Dimensions (W×D×H) 190 × 44.5 × 478 mm (including ears)
190 × 44.5 × 440 mm (without ears)
Serial line protection 15 KV ESD for all signals
Magnetic isolation 1.5 KV for Ethernet
Power line protection 4 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
Regulatory approvals FCC Class A, CE Class A, UL, CUL, TÜV
Copyright © 2006
Moxa Technologies Co., Ltd.
All rights reserved.
Reproduction without permission is prohibited.
Tel: +886-2-8919-1230
www.moxa.com
Fax: +886-2-8919-1231
support@moxa.com.tw