User`s manual

NPort 5600-8-DT User’s Manual Other Configuration Interfaces
9-3
Stop bit
Parity
Flow control
Tx/Rx fifo
Interface
Tx/Rx bytes
Line status
Main MenuÆOp Mode set
Under Op Mode set, you can view or modify each device port’s operation mode. You will first
select the port that you wish to modify or view. Note that you can only select the operation mode.
You will not be able to view or modify the advanced operation mode settings through the LCM
console.
Main MenuÆConsole
Under Console, you can enable or disable the web and Telnet consoles. The following fields are
displayed:
Web console
Telnet console
Main MenuÆAlarm
Under Alarm, you can adjust the settings for the WAV file that is used for the audio alarm. The
following fields are displayed:
Volume
Audition
Del User Audio
Use Volume to adjust the volume of the audio alarm. Use Audition to test the audio alarm. Use
Del User Audio to delete the WAV file. Note that deleting the WAV file will disable the audio
alarm.
Main MenuÆLCM passwd prot
LCM passwd prot refers to password protection for the LCM. If password protection is enabled,
users will be required to enter the password in order to use the LCM console.
Main MenuÆReset btn prot
Reset btn prot refers to reset button protection. If reset button protection is enabled, you will only
be able to use the reset button in the first 60 seconds after powering on the NPort. After 60 seconds,
the reset button will be disabled.