NPort 5600-8-DT User’s Manual Operation Mode Advanced Settings
6-7
Other Parameters
Local TCP port
Real COM Mode
TCP Server Mode
TCP Client Mode
UDP Mode
Reverse Telnet Mode
Pair Connection Mode
RFC2217 Mode
Range: 1 to 65535
Default: 4001 for port 1, 4002 for port 2, etc.
Description: This specifies the TCP port number for
communication to the attached device. Socket applications
will need to refer to the device using this port number. For
Pair Connection modes, this field specifies the slave’s port
number, and the same value must be used for the master’s
Destination IP parameter.
Command
port
Real COM Mode
TCP Server Mode
TCP Client Mode
UDP Mode
Reverse Telnet Mode
Pair Connection Mode
RFC2217 Mode
Range: 1 to 65535
Default: 966
Description: This specifies the TCP port number for MOXA
IP-Serial Library commands. You do not need to reference
this port number in your application when using the MOXA
IP-Serial Library, since the library automatically obtains the
number from the device server. Change this setting only if
there is a port number conflict with another application or
device.
Destination IP address
Real COM Mode
TCP Server Mode
TCP Client Mode
UDP Mode
Reverse Telnet Mode
Pair Connection Mode
RFC2217 Mode
Range: N/A
Default: none
Description: This specifies the IP address for the slave end of a
pair connection.
Destination IP address 1 through 4
Real COM Mode
TCP Server Mode
TCP Client Mode
UDP Mode
Reverse Telnet Mode
Pair Connection Mode
RFC2217 Mode
Range: N/A
Default: none
Description: This specifies the network host(s) that will access
the device. Serial data will be transmitted to every address
listed, and network data will be sent to the device on a first-