User`s manual

UC-7112-LX Plus Software User’s Manual Managing Embedded Linux
3-8
Adjusting the System Time
Setting the Time Manually
The UC-7112-LX Plus has two time settings. One is the system time, and the other is the RTC
(Real Time Clock) time kept by the UC-7112-LX Plus’s hardware. Use the
#date
command to
query the current system time or set a new system time. Use
#hwclock
to query the current RTC
time or set a new RTC time.
Use the following command to query the system time:
#date
Use the following command to query the RTC time:
#hwclock
Use the following command to set the system time:
#date MMDDhhmmYYYY
MM = Month
DD = Date
hhmm = hour and minute
YYYY = Year
Use the following command to set the RTC time:
#hwclock –w
Write current system time to RTC
The following figure illustrates how to update thesystem time and set the RTC time.
192.168.3.127 – PuTTY
root@Moxa:~# date
Fri Jun 23 23:30:31 CST 2000
root@Moxa:~# hwclock
Fri Jun 23 23:30:35 2000 -0.557748 seconds
root@Moxa:~# date 120910002004
Thu Dec 9 10:00:00 CST 2004
root@Moxa:~# hwclock –w
root@Moxa:~# date ; hwclock
Thu Dec 9 10:01:07 CST 2004
Thu Dec 9 10:01:08 2004 -0.933547 seconds
root@Moxa:~#