Specifications

fSTOP Wireless V2-1 BarTech Receiver Manual 30-Dec-13
PLC Electronic Solutions Ltd. Copyright © 2013
www.plcelectronicsolutions.com 9 of 20
3.5. Automatic Motor Calibration
For lenses with end stops (most camera lenses).
a. Set the AUTO/MANUAL switch up to AUTO on the front of the fSTOP Wireless V2-
1.
b. Insure that the torque is set to the minimum usable setting before connecting the
motor to a lens. See section 3.7. TORQUE Setup.
c. After installing the motor and fSTOP Wireless V2-1 power up the camera system.
The motor will automatically calibrate by moving the lens gear to both end stops. It
is now ready to communicate with your BFD Handset.
*The fSTOP Wireless V2-1 has built-in positional memory. The fSTOP Wireless V2-1 will
use the calibration stored in its memory until the motor is removed or the unit is powered
down for more than 45 minutes, or the CAL button is pressed.
Note: Do not let the motor spin for more than 60 seconds, as it will fail calibration as
it assumes that no lens is present. If this happens simply press the CAL button on
the front of the fSTOP Wireless V2-1 or unplug the motor cable and then plug it in
again to restart the calibration.