Specifications
fSTOP Wireless V2-1 BarTech Receiver Manual 30-Dec-13
PLC Electronic Solutions Ltd. Copyright © 2013
www.plcelectronicsolutions.com 13 of 20
3.9. Resetting Calibration
a. Press the CAL or calibrate button while the fSTOP Wireless V2-1 is powered will do
a soft reset of the unit.
b. When the button is depressed and released it will reset the unit. The motor will then
start it’s calibrate function again immediately if in Automatic calibration mode or be
ready for settings in Manual calibration mode. Limits will also be erased.
3.10. Resetting to Factory Defaults
Resetting the fSTOP Wireless V2-1 to factory defaults will clear out all of the settings.
a. Make sure that the fSTOP Wireless V2-1 is powered down and the
AUTO/MANUAL switch is in the up/AUTO position.
b. Power up the fSTOP Wireless V2-1 while holding in the CAL button until the lights
cycle at the same time from red to orange to green then release the CAL button.
The unit is now set to factory defaults.