7 Environmental Ratings and Reliability Test
7.1 Environmental Parameters
SYM PARAMETER MIN TYP MAX UNITS
Toper Operating Temp 0 25 85 °C
Tstore Storage Temp -40 - 70 °C
Hrel Relative Humidity (non-
condensing) @ 60°C
10 - 90 Percent
Ss Shock Survivability 75 - - cm
Alt_op Altitude, Operating 0 - 3,000 m
Alt_st Altitude, Storage 0 - 12,000 m
The unit should not be subjected to direct sunlight for extended periods of time.
7.2 Reliability Test Criteria [A]
# PARAMETER MIN Reference
A1 Appearance & Size
Any conspicuous deformation, crack, loose joint is not
allowed.
A2 Functional Test over
Voltage Range
Unit must be functional over the voltage range:
Operating Voltage
6.5
A4 Standby Current
Must meet I Standby 5.6
A5 RF Frequency
Must meet RF frequency specification 6.7
7.3 Electrostatic Discharge (ESD) Requirements
The transceiver will be tested at the system level to the CE testing specifications.