6.2.7. Basic settings
F07
Range
Default
Ser.
062
Operation mode of the counter
0 … 10
0
F2
0=
„Single“, encoder 1 only
1=
„Sum“, encoder 1 + encoder 2
2=
„Differential“, encoder 1 – encoder 2
3=
Master counter and batch counter
4=
Measuring of real cutting length
5=
Calculation of roll diameters
6=
Calculation of roll radius
7=
Cut-to-length control
8=
Cut-to-length control
9=
Slip-, torsion- skew position monitor
10=
Dual counter, independent counters 1 and 2
063
Decimal point position of encoder 1
0 … 5
0
F3
064
Decimal point position of encoder 2
0 … 5
0
F4
065
Decimal point position combined <1&2>
0 … 5
0
F5
066
Scaling factor for combined values <1&2>
0.0001 – 9.9999
1.0000
F6
067
Divider for combined values*
0.0000 – 9.9999
0
F7
068
Offset value for combined values
-199999 - 999999
0
F8
069
Brightness of the 7-segment LED display
0 … 4
0
F9
0=
100% of maximum brightness
1=
80% of maximum brightness
2=
60% of maximum brightness
3=
40% of maximum brightness
4=
20% of maximum brightness
070
Display Update Time (sec.)
0.005 - 9.999
0.005
G0
6.2.8. Analogue output definitions (ZA models only)
F08
Range
Default
Ser.
074
Output format
0 … 3
0
G4
0=
Voltage – 10 V… + 10 V
1=
Voltage 0 ….. +10 V
2=
Current 4 – 20 mA
3=
Current 0 – 20 mA
075
Beginning of the conversion range
-199999 - 999999
0
G5
Display value to generate 0 volts or 0/4 mA
076
End of the conversion range
-199999 - 999999
10 000
G6
Display value to generate 10 volts or 20 mA
077
Analogue output swing (1000 = 10 V or 20 mA)
0 … 1000
1000
G7
078
Analogue zero offset (mV, zero displacement)
-10000 - 10000
0
G8
079
Analogue output assignment
(according to lines 1 – 5 of the display scrolling function)
0 … 4
(Line1) … (Line5)
G9
*) Setting 0,0000 will skip the whole recalculation and therefore speed up the cycle time