Datasheet

ZD34007c_e.doc / Nov-15 Page 32 / 50
6.2.5. Keypad protection codes
F05
Range
Default
Ser.
033
Protected group F01
0
C3
034
Protected group F02
0
C4
035
Protected group F03
0 = no protection
0
C5
036
Protected group F04
6079
C6
037
Protected group F05
1 999 999 =
0
C7
038
Protected group F06
Protection code
0
C8
039
Protected group F07
for the actual
0
C9
040
Protected group F08
group
0
D0
041
Protected group F09
0
D1
042
Protected group F10
0
D2
043
Protected group F11
0
D3
044
Protected group F12
0
D4
045
Protected group F13
0
D5
6.2.6. Key commands and control input definitions
F06
Range
Default
Ser.
050
Function assignment to key „UP“
0 … 14
0
E0
0=
No function
1=
Reset counter 1 (encoder 1) and read **)
(Clears also points of change of direction)
2=
Reset counter 2 (encoder 2) and read **)
3=
Reset counter 1 and counter 2 and read **)
4=
Set counter 1 to Set Value 1 *)
5=
Set counter 2 to Set Value 2 *)
6=
Set both counters to Set Value *)
7=
Inhibit counter 1 and read **)
8=
Inhibit counter 2 and read **)
9=
Read front thumbwheels (models 6xx only) **)
10=
Start serial transmission
11=
Reset minimum/maximum records
12=
Scroll actual display
13=
Special command (depends on counter mode)
14=
n.a.
051
Function assignment to key „DOWN“
0 … 14
0
E1
See key „UP“
052
Function assignment to key „ENTER“
0 … 14
0
E2
See key „UP“
*) Parameter F10.101 defines the source of the Set Value (see 6.3)
**) “Read” refers to models 6xx with thumbwheel switches only. See appendix.