Datasheet
ZD34007c_e.doc / Nov-15 Page 30 / 50
6.2. Description of the Parameters
6.2.1. Preselections and presets
F01
Range
Default
Ser.
000
Preselection K1
-199 999 - 999 999
1 000
00
001
Preselection K2
-199 999 - 999 999
2 000
01
002
Preselection K3
-199 999 - 999 999
3 000
02
003
Preselection K4
-199 999 - 999 999
4 000
03
004
Preset value encoder 1
-199 999 - 999 999
000 000
04
Upon internal or external command the encoder 1
counter will set to this value
005
Preset value encoder 2
-199 999 - 999 999
000 000
05
Upon internal or external command the encoder 2
counter will set to this value
6.2.2. Definitions for encoder 1
F02
Range
Default
Ser.
010
Encoder properties
0 … 3
1
A0
0=
Differential signals A, /A, B, /B (2 x 90°)
*)
1=
HTL signals A, B (2 x 90°) single-ended
2=
Differential signals A, /A for count *)
Differential signals B, /B to indicate static
direction (if available)
3=
HTL signal A (single-ended) for count
HTL signal B (single-ended) to indicate static
direction (if available)
011
Edge counting
0 … 2
0
A1
0=
Simple (x1)
1=
Double (x2)
2=
Full quadrature (x4)
012
Counting direction
0 … 1
0
A2
0=
Up when A leads B
1=
Down when A leads B
013
Impulse scaling factor
0.00001 - 9.99999
1.00000
A3
Multiplier for input impulses
014
Impulse multiplier
001 - 99
001
A4
Multiple count of every impulse
015
Round-loop cycle
0 - 999 999
0
A5
0=
Unlimited counting range
xxx
Round-loop operation in a range 0 - xxx
*) Applies for any kind of differential signals, no matter if RS422 or TTL level or HTL level