Ip251_02b_oi_e.doc / Dez-15 Page 22 / 28
7.5. Parameters for RS232 settings
Parameter
Description
Unit Number :
Any address numbers between 11 and 99 * can be chosen
(Factory setting = 11).
* Please note: The address must not contain a “0“ because
these numbers are reserved for collective addressing.
Serial Baud
Rate:
Setting
Baud-Rate
0*
9600
1
4800
2
2400
3
1200
4
600
5
19 200
6
38 400
* = Factory setting
Serial Format:
Setting
Data bits
Parity
Stop bits
0
7
even
1
1
7
even
2
2
7
odd
1
3
7
odd
2
4
7
none
1
5
7
none
2
6
8
even
1
7
8
odd
1
8
8
none
1
9
8
none
2
* = Factory setting
Serial Protocol:
Determines the sequence of characters sent, when you use the serial
output for cyclic data transmission under timer control
(xxxxxxx is the measuring value transmitted). The length of the transmitted
value is dependent on its current value.
Both print formats are shown in the following table:
Unit No.
Serial Protocol = 0*:
1
1
+/-
X
X
X
X
X
X
LF
CR
Serial Protocol = 1 :
+/-
X
X
X
X
X
X
LF
CR
* = Factory setting