6.2.9. Special functions
F08
Range
Default
F08.064
Digital input filter: must be set to “0”.
0 … 3
0
F08.065
Trigger threshold for encoder1 inputs *)
30 … 250
166
F08.066
Trigger threshold for encoder2 inputs *)
30 … 250
166
F08.067
Brightness of the 7-segment LED display
0 … 4
0
0=
100% of maximum brightness
1=
80% of maximum brightness
2=
60% of maximum brightness
3=
40% of maximum brightness
4=
20% of maximum brightness
F08.068
Frequency Control: must be set to “0”
0 … 1
0
F08.069
Length Storage
0 … 1
0
0=
Cutting length set by the “Direct Fast Access”
menu (see chapter 5.3) is only temporary active
until next power-down.
1=
Cutting length set by the “Direct Fast Access”
menu (see chapter 5.3) is stored to EEPROM for
enduring use.
F08.070
Display Time: Update time (sec.) for display only
0.005 … 9.999
0.050
F08.071
Default Display: Number of actual value displayed by
the unit after power up (see table in chapter 7.1 at
description of Scroll Display command)
0 … 8
0
*) Must be set to the default value (166) for any kind of input signals, except for single-
ended TTL signals which require a setting of 35.
6.2.10. Keypad protection codes
F09
Range
Default
F09.072
Protected group F01
F09.073
Protected group F02
0
F09.074
Protected group F03
0 = no protection
F09.075
Protected group F04
F09.076
Protected group F05
1 – 999 999 =
F09.077
Protected group F06
Protection code
F09.078
Protected group F07
for the actual
F09.079
Protected group F08
parameter group
F09.080
Protected group F09