6.2.3. Definitions for the Master Encoder
F03
Range
Default
F03.026
Encoder properties
0 … 3
1
0=
Differential Impulses A, /A, B, /B (2 x 90°) incl. inv.
1=
Single-ended Impulses A, B (2 x 90°) without inv.
F03.027
Edge counting
0 … 2
0
0=
Simple edge evaluation (x1)
1=
Double edge evaluation (x2)
2=
Full quadrature edge evaluation (x4)
F03.028
Counting direction
0 … 1
0
0=
Up when A leads B
1=
Down when A leads B
F03.029
Speed Display Factor
Multiplication factor to calculate the speed display value
from the master frequency (see chapter 7.3)
1 … 999999
1
F03.030
Speed Display Divider
Divider to calculate the speed display value from the master
frequency (see chapter 7.3)
1 … 999999
1
F03.031
Speed Display Dec.Point
Position of decimal point for the speed display value (see
chapter 7.3)
0 … 5