Datasheet
Dz210_01c_oi_e.doc / Nov-15 Page 10 / 14
4.3. Setting of the Standstill Time (T)
Provided that the standstill function has been assigned to relay 2 and output 2 by setting DIL
switch 1 position 7 to ON, a standstill definition can be set by means of positions 1 - 4 of the
switch DIL 2. The table indicates the pause time between two input pulses that must be
exceeded in order to signal "standstill".
DIL 2
DIL 2
1 msec
ON
ONOFF
256 msec
ON
ONOFF
2 msec
ON
512 msec
ON
4 msec
ON
1.024 sec
ON
8 msec
ON
2.048 sec
ON
16 msec
ON
4.096 sec
ON
32 msec
ON
8.192 sec
ON
64 msec
ON
16.384 sec
ON
128 msec
ON
32.768 sec
ON