Instructions

Ax350_06a_oi_e.docx / Aug-19 page 61 / 78
Application specific commands
Name
Index
Subindex
Value
Description of the action
Dynamic (d)/
static (s)
TARA INPUT 1
2
0
160
Value of input 1 is stored as an
offset from input 1.
(d)
TARA INPUT 2
2
0
161
Value of input 2 is stored as an
offset from input 2.
(d)
TARA INPUT 1 + 2
2
0
162
Value of input 1 is stored as an
offset from input 1,
value of input 2 is stored as an
offset from input 2
(d)
ADD TO TOTAL 1
2
0
163
Adds the current value from input 1
to INPUT 1 TOTAL.
(d)
ADD TO TOTAL 2
2
0
164
Adds the current value from input 2
to INPUT 2 TOTAL.
(d)
RESET TOTAL 1
2
0
165
Value of totalizator 1 is reset to 0.
(d)
RESET TOTAL 2
2
0
166
Value of totalizator 2 is reset to 0.
(d)
RESET TOTAL LINKAGE
2
0
167
Value of totalizator 1 and 2 are
reset to 0.
(d)
TEACH PRESELECTION 1
2
0
168
Value (SOURCE 1) is saved as
PRESELECTION 1.
(d)
TEACH PRESELECTION 2
2
0
169
Value (SOURCE 2) is saved as
PRESELECTION 2.
(d)
TEACH PRESELECTION 3
2
0
170
Value (SOURCE 3) is saved as
PRESELECTION 3.
(d)
TEACH PRESELECTION 4
2
0
171
Value (SOURCE 4) is saved as
PRESELECTION 4.
(d)
SCROLL DISPLAY
2
0
172
Display switching.
(d)
SERIAL PRINT
2
0
173
Send serial data, see SERIAL
VALUE.
(d)
SET TO RED
2
0
174
Display lights up red. The color can
be chanced by the event-dependent
color switching in the
PRESELECTION 1 … 4 MENU
(d)
SET TO GREEN
2
0
175
Display lights up green. The color
can be chanced by the event-
dependent color switching in the
PRESELECTION 1 … 4 MENU
(d)
SET TO YELLOW
2
0
176
Display lights up yellow. The color
can be chanced by the event-
dependent color switching in the
PRESELECTION 1 … 4 MENU
(d)
CLEAR MIN/MAX
VALUES
2
0
177
Reset of min/MAX values
(s)
CLEAR LOOP TIME
2
0
178
Loop time Reset
(d)
ACTIVATE DATA
2
0
179
N.A.
(d)
STORE EEPROM
2
0
180
Current parameter set is stored non-
volatile in the EEPROM.
(d)
TESTPROGRAMM
2
0
181
Starts or stops the test program
(s)
FREEZE
2
0
182
Freeze the display value.
(s)
KEY LOCK
2
0
183
Keypad Lock: Touchscreen.
(s)