Maintenance Procedures
The following maintenance procedures should be performed on a routine basis:
1. Carefully clean the exterior with a soft cloth to keep the cabinet looking new. Check the cabinet for
dents or impact markings, if found, inspect for damaged components.
2. Check all hoses and wires for cuts or frays.
3. Clean the unit’s lter screens after every 100 services or 6 months, which ever comes rst.
Cleaning the Unit’s Filter
1. Disconnect power harness from power source.
2. Remove the eight Phillip head screws from the unit’s back panel. Unsnap the lamp from back panel and
set back panel aside.
3. Locate the bell shaped plastic lter housing, found at the top of each tank. A clear plastic ½” hose runs
from each lter housing to a pump. NOTE: Clean one lter at a time.
4. Remove the lock clip from the bell shaped plastic lter. Hold the bottom half of the lter while rotating the
top half of the lter counter-clockwise until the four lock tabs clear. Then separate the two pieces by lift-
ing up the top half of the lter.
5. Use a ne pick or bent pin to pull screen away from the lter housing. Clean screen.
6. Assemble in reverse order. NOTE: Use caution not to pinch O-ring on reassembly
7. Enter initials, date, and a check mark in the appropriate boxes of the Maintenance Record section of this
user manual.