Owner's manual

info@motorvac.com www.motorvac.com
TransTech III Auto-Prime Procedure
(For rst time set-up only)
Set-Up Instructions:
1. Check the output/return hoses, battery connections, and all external components for damage.
2. Fill the CLEAN FLUID tank with approximately 6 quarts (5.7 liters) of new ATF.
3. Connect two compatible adapters to each other, secure tightly. Attach the CLEAN FLUID & INLINE
RETURN hoses together using the connected adapters. Ensure that both hoses have no kinks or visual
damage.
4. Place the waste hose into the clean tank ll neck with the ball valve open.
5. Attach the units’ red (+) battery clip to vehicle’s positive battery terminal; connect the black (-) battery clip
to a solid ground point as far from the battery as possible.
6. Press and hold the CHANGE FLUID button for 5 seconds until the unit sounds the alarm. The FILL and
DRAIN LEDs will ash. Press and hold the CHANGE FLUID button again for 5 seconds until the unit
sounds the alarm. The DRAIN, FILL and COMPLETE LEDs will cycle in a clockwise direction while the
unit is performing the Auto-Prime procedure. The unit will pump uid from the clean tank to the waste
tank. The unit will then set the waste tank zero level by pumping uid from the waste tank into the clean
tank
7. Return the hoses to their original location.
8. The initial setup is complete.
8