User manual

AP User Manual January 2004
Software Release 4.1
Table 12 identifies by MAC address whether a module auto-senses the Ethernet cable type.
Table 12: Module auto-sensing per MAC address
Module Type
MAC Address
(ESN) of Non Auto-
sensing Module
MAC Address
(ESN) of Auto-
Sensing Module
2.4-GHz modules (no ESNs) (all ESNs)
5.2 Modules 0a003e0021c8 0a003e0021c9
5.7 Modules 0a003ef00f79 0a003ef00f79a
Where a non auto-sensing module is used
use an RJ-45 straight-thru cable to connect to a NIC (network interface
card).
use an RJ-45 crossover cable to connect to a hub, switch, or router.
Where the Canopy AC wall adapter is used
the +V is +11.5 VDC to +30 VDC, with a nominal value of +24 VDC.
the maximum Ethernet cable run is 328 feet (100 meters).
7.2.2 Recommended Tools
The following tools may be needed for cabling the AP:
RJ-11 crimping tool
RJ-45 crimping tool
electrician scissors
wire cutters
cable testing device.
7.2.3 Connector Wiring
The following diagrams correlate pins to wire colors and illustrate crossovers where applicable.
Issue 5 Page 63 of 102