Specifications

FIXED NETWORK EQUIPMENT
QUANTAR® Data Base Station Equipment
R4-11-4G Equipment Descriptions 4-19
ALT: DC ONLY OP. DC
TO DC CONVERTER
X113 Adds a 48/60V DC 210 watt (low power) DC-to-DC converter
instead of an AC power supply. Comes with a battery backup
cable (TKN8732) and a 10-foot external battery cable
(TRN5155). A 48/60V DC battery or power source is required.
ALT: CONVERTER DC
TO DC 48/60V HP
X113 Adds a 48/60V DC 600 watt (high power) DC-to-DC converter
instead of an AC power supply. Comes with a battery backup
cable (TKN8732) and a 10-foot external battery cable
(TRN5155). A 48/60V DC battery or power source is required.
ALT: DC ONLY
OPERATION (DC TO
DC)
X121 Adds a 12/24V DC 210 watt DC-to-DC converter instead of an
AC power supply. Comes with a battery backup cable (TKN8732)
and a 10-foot external battery cable (TRN5155). Required for low
power stations being operated from batteries. A 12/24V DC
battery or power source is required.
ADD: HARDWARE,
RACKMOUNT
X153 Adds a set of two mounting extensions with eight screws
included. The size is four-and-a-half-inches wide, eight and three-
quarters inches long, and 11/16-inches deep. It is used with the
seven, seven-and-a-half, and eight-foot open racks to distribute
the weight more evenly.
ALT: CABINET,
INDOOR 60”
X180 Adds a 60-inch housing for the base station. This is the largest
size enclosed housing (30 rack units) for a DBS. Cabinet can
hold two DBSs without duplexers.
ADD: DPXR, QTAR/
QTRO VHF/UHF/800/
900
X182* Adds a duplexer (TDF6980 and installation hardware) for full
duplex operation. This option is mandatory for maximum data
throughput.
•NOTE: Systems engineers can choose not to include the
X182 if they are using other combining devices. Separate
receive and transmit antennas are not recommended.
ADD: 800 20W PA X250 Adds a low power RF power amplifier to the base station.
ALT: CABINET,
INDOOR 46”
X308 Adds a 46-inch housing for the base station. This is the medium
size enclosed housing (23 rack units) for a DBS.
ADD: DATA BASE
STATION OPER
X399 C Adds an enhanced performance integrated controller card to the
station to support the additional functions and features required in
a data configuration. This option is mandatory.
ALT: MODULAR RACK,
30”; 16 RACK UNIT
X741 Adds a 30-inch high modular rack that supports 16 rack units.
ALT: MODULAR RACK,
45”, 24 RACK UNIT
X742 Adds a 45-inch high modular rack that supports 24 rack units.
ALT: MODULAR RACK,
52”,27 RACK UNIT
X743 Adds a 52-inch high modular rack that supports 27 rack units.
ADD: 100W 800MHZ
OPERATION
X750 Adds a high power RF power amplifier to the base station.
Table 4-14. Hardware Options for QUANTAR DBS (Continued)
COF DESCRIPTION
OPTION
NUMBER
DESCRIPTION