Installation
GENERAL
This chapter provides information for the mechanical
and electrical installation of the modem.
SITE
SELECTION
Install the modem within 6 feet of a standard 115 or
230 Vac grounded wall outlet as required for the
specific model and no further than 50 feet from the
terminal equipment.
The installation area should be clean and free from
extremes of temperature, humidity, appreciable
shock, and vibration. See equipment specifications
in Appendix A for details. Allow clearance for
operation and maintenance and at least 4 inches at
the rear for cables and air flow.
Receipt
Inspection
After unpacking the equipment, check the contents
against the packing list. Inspect the equipment for
any damage that may have occurred in shipment. If
any damage or equipment shortage is noted, refer to
the warranty literature. Keep the shipping container
and material.
Tools Required
Normal installation requires a screwdriver to secure
the data terminal equipment (DTE) cable to the mo-
dem and to attach the telephone cable to the 42A
terminal block for leased line operation.