Specifications

V.3229 / V.3229L <C#>-11
<Re
f
erence>
Operation
REMOTE
CONFIGURATION
This mode of operation allows viewing or modifying
the options of a remote modem that supports Motor-
ola UDS remote configuration. Remote configura-
tion is initiated by the local (master) modem through
a routine incorporating remote digital loopback, a
security code, and an acknowledgment from the re-
mote (slave) unit to be modified. The security code
is user programmable and provides protection from
unauthorized entry. The modems are shipped from
the factory without a security code. Refer to Remote
Configuration in Chapter 5.
The ATD and AT&T commands are not accepted in
remote configuration.
Note: Remote configuration is supported at all rates
except 300 bps.
Remote
Configuration
Security
The correct code must be received by the remote
modem before remote configuration can be estab-
lished. Once established, the local DTE becomes a
virtual terminal and can serve both local and remote
modems. After starting remote configuration, the
local DTE serves the remote modem.
To return DTE service to the local modem while in
remote configuration, issue the +++ escape se-
quence.