Specifications

V.3229 / V.3229L <C#>-K
<Re
f
erence>
Command Index and Defaults
STATUS REGISTERS
S-Reg RO/RW Page Function Default
S0 RW 6-6 Ringtoanswer 1
S1 RO 6-6 Ring count
S2 RW 6-6 Escape sequence character 43 (+)
S3 RW 6-6 End-of-line character 13 (CR)
S4 RW 6-6 Line feed character 10 (LF)
S5 RW 6-6 Backspace character 8 (BS)
S6 RW 6-7 Pause before blind dialing 2 (2 sec)
S7 RW 6-7 Pause for carrier 30 (30 sec)
S8 RW 6-7 Pause for comma 2 (2 sec)
S9 RW 6-7 Carrier validation 6 (0.6 sec)
S10 RW 6-7 Loss carrier delay time 14 (1.4
sec)
S11 RW 6-7 DTMF tone duration 80 (80 ms)
S12 RW 6-8 Escape sequence pause 50 (1 sec)
S14 RW 6-9 Bit mapped
S16 RO 6-10 System tests 0
S18 RW 6-10 Test timer 0
S21 RW 6-11 Bit mapped
S22 RW 6-12 Bit mapped
S23 RW 6-12 Bit mapped
S25 RW 6-13 DTR recognition time 5 (0.5 sec)
S26 RW 6-13 RTS/CTS delay 0
S27 RW 6-13 Bit mapped
S28 RW 6-13 Lookback timer 15 min
S29 RW 6-14 Bit mapped
S30 RW 6-14 V.25 mode selection
S31 RW 6-15 4-wire leasded line train
S32 RW 6-15 Bit mapped
S34 RW 6-16 Bit mapped
S39 RW 6-16 Connect message rate 0
S51 RW 6-17 Bit mapped -10 dBm
S52 RW 6-17 Bit mapped
S53 RW 6-17 801 V.32 timeout 0 (long)
S54 RW 6-18 Flow control DTE 0
S56 RW 6-18 V.42 compression
S57 RW 6-19 Number code application 0