Specifications

<C#>-J V.3229 / V.3229L
<Re
f
erence>
Command Index and Defaults
* factory default
Command Page S-Reg Description
*TDn 5-33 S52 Sets dial transmit level to n where n is
a number between 9 and 21 corresponding
to -9 to -21 dBm
*TLn 5-33 S52 Sets leased line transmit level to n
where n is a number between 0 and
21 corresponding to 0 to -21 db
$V 5-30 Display product serial number
Security Commands
$S=x 5-40 Sets an empty password location to x
$C=x,y 5-40 Changes either password where x
represents the old password and y is
the new one
$C=x,- 5-40 Deletes password x from memory
$DR 5-40 Reset security
$D? 5-40 Displays the current status of security
$D=x 5-40 Disables security where x is either
password
$E=x 5-40 Enables security where x is either
password
$E? 5-40 Displays the current security status