Test Procedures
¥An alternative to the above procedure is to request
the operator at the remote modem to place his modem
in LOCAL ANALOG LOOP and enable his bilateral
analog option. This places the remote modem in
local analog loop test. It also connects the transmit
phone line to the receive phone line through a buffer
amplifier stage. At the local modem, configure for
TEST PATTERN. The test pattern transmitted by
the local modem is looped around through a buffer
stage at the remote modem and back to the local
modem.
¥At the local modem, the front panel indicators under
ideal conditions should be:
¥The TEST PATTERN ERRORS display counts re-
ceived errors.
In this test you are connecting two telephone line
links in series, doubling the distortion effects. A
telephone link indicated as marginal by this test may
be satisfactory as used in normal operation.
¥After determining the quality of the telephone lines,
exit the test.
¥If fault remains unidentified, call Technical Servic-
es.
AT COMMAND
RECOVERY FOR L
MODELS
For the L model of the modem, holding the TALK/
DATA button down for 5 seconds reenables AT
commands. The TALK LED flashes 3 times to
indicate that the command set has been loaded.