Specifications

<C#>-B V.3229 / V.3229L
<Re
f
erence>
Test Procedures
FALLBACK RATES
Since there is no standard fallback procedure from
V.32b rates to V.22 rates, problems may arise when
a V.32 optioned for 14400 originates a call to a V.22
bis modem. If this is a problem, change the originate
modem speed to 2400 bps from the front panel or
with the AT command AT%B3.
MODEM AND
TELEPHONE LINE
CHECK
Step 1
¥Configure the modem for LOCAL ANALOG
LOOP WITH TEST PATTERN. This forces the
modem on hook, terminates the local modem leased
lines into 600 ohms, and connects the local modem
transmit output amplifier back to its own receiver.
Transmit input data from the terminal is inhibited and
is substituted with a V.52 test pattern.
¥This test checks operation of the local modem mod-
ulator and demodulator circuitry and should be at-
tempted at both local and remote sites if operators are
available.
¥When errors are present, the TEST PATTERN ER-
RORS display counts errors.
Note: The following LED illustrations show indica-
tions for diagnostic tests. These indications are valid
when DTE options are set by factory option set #1
and RTS is active from the DTE. Where indicated