Specifications

<C#>-2 V.3229 / V.3229L
7
V.25 bis Autodialer
V.25 bis as described in the following text. Param-
eters are separated by semicolons.
For example:
PRN a;nnn...n
where a=the phone number ad-
dress in memory and nnn . . . n
= the phone number
The a and the nnn...n are both parameters.
Not all commands have parameters. For example the
CIC command has no parameter.
GUIDELINES
Use the following guidelines when working with
V.25 bis software:
¥An indicator enclosed in less than / greater than
signs < > represents a specific character in the appro-
priate character set, ASCII or EBCDIC.
<sp> - space
¥Each response below is considered an individual
message per V.25 bis conventions. A dial command
with intermediate call progress enabled (sync mode
ASCII/EBCDIC character set) is illustrated:
From DTE
To DTE
<sy><sy><stx>CRN<sp>(205)555-0124<etx>
<sy><sy><stx>VAL<etb>
<sy><sy><stx>CNX<sp>@9600BPS
<etx>
¥Spaces in a command from the DTE are optional and
ignored.