Status Registers
AT&L1 selects leased line operation (sets S27
bit 2 to 1)
Individual bit method:
ATS27.2=0 selects dial-up operation (sets S27
bit 2 to 0)
ATS27.2=1 selects leased line operation (sets
S27bit2to1)
Note: This way of selecting options can be used on
all S-registers except read only registers.
Autoanswer
S0=0-255
This register turns the option on or off. Set the
register to 0 to turn autoanswer off.
Set the register to any value other than zero (1-255)
to turn autoanswer on. The number selected is the
ring count the modem answers on. For example, if
S0 equals 4, the modem answers the call on the fourth
ring. The default value is 1.
Ring Count
S1=0-255
This register contains the ring count for a current
incoming call and should not be changed. The user
can read the register to determine the ring total.
Escape Character
S2=0-255
The standard escape character is a + sign (ASCII
value of 43). To change the character, set S2 to the
desired ASCII value.