Specifications

<C#>
Introduction
V.3229 / V.3229L <C#>-5
<Re
f
erence>
Installation
Programmable mode corrects for the signal level loss
between the modem and the telephone company
central office. This is done by setting the modem
transmit output signal level with a resistor selected
and installed in the jack by the telephone company.
This allows the output signal to reach the central
office at the optimum level of -12 dBm. Jack ar-
rangements for this mode are the RJ45S (Program-
mable) and RJ41S (Universal). The RJ41S has a
switch option that must be selected to Programmed
(P). Cable PN 61020192-0301 (not supplied with
modem) is used to connect the DIAL jack to the
RJ41S or RJ45S wall jack.