Specifications

<C#>-48 V.3229 / V.3229L
5
A
synchronous Operating Commands
*default
Reset to Stored
Configuration
Z
The Z commands reset the modem and immediately
load either user option set 1 or 2 as the current
configuration. This command saves time once a
proven configuration is established.
View Configuration
Profiles / Received
Signal Options
&V
&F2 Load factory option 2 (async dial-up
without V.42 bis)
&F3 Load factory option 3 (sync dial-up
without V.42 bis)
&F4 Load factory option 4 (sync 4-wire
leased line without V.42 bis)
&F5 Load factory option 5 (async 4-wire
leased line with V.42 bis)
&F6 Load factory option 6 (async 4-wire
leased line without V.42 bis)
&F7 Load factory option 7 (sync 2-wire
leased line normal originate)
&F8 Load factory option 8 (sync 2-wire
leased line forced answer)
&F9 Load factory option 9 (sync V.25 bis
dialer)
Table 42:
Command Operation
Z Resets the modem and immediately
loads user option set 1
Z1 Resets the modem and immediately
loads user option set 2
Table 41:
Protoco
lC
omman
d
s,
C
ont.