Specifications

11 - 2 Symbol DS3407 Product Reference Guide
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Miscellaneous Scanner Parameter Defaults
Table 11-1 lists the defaults for miscellaneous scanner options parameters. There are two ways to change the
default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, scan the *Restore Defaults bar code on page 4-4.
Download data through the device’s serial port using SSI. Hexadecimal parameter numbers appear in this
chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar codes.
See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters
using this method.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and
miscellaneous default parameters
Table 11-1
Miscellaneous Scanner Options Default Table
Parameter
Parameter
Number
Default
Page
Number
Transmit Code ID Character 2Dh None
11-3
Prefix Value 63h, 69h 7013 <CR><LF>
11-4
Suffix 1 Value
Suffix 2 Value
62h, 68h
64h, 6Ah
7013 <CR><LF>
11-4
Scan Data Transmission Format EBh Data as is
11-5
FN1 Substitution Values 67h, 6Dh Set
11-6
Transmit “No Read” Message 5Eh Disable
11-7